PRODUCTS

Catalog Number:FS1070R
FS-Rat ACTH(Adrenocorticotropic Hormone) ELISA Kit
Copy Product Information

Size:

96 T

48 T

Price:

Inquiry

Inquiry

Delivery: Order now, ship in 3 days

Product Details
Product Name FS-Rat ACTH(Adrenocorticotropic Hormone) ELISA Kit Species Rat
Uniprot ID N/A Alternative Names Corticotropin, Adrenocorticotropin
Detection method Competitive Sensitivity 9.38 pg/mL
Standard 1000pg/mL Detection Range 15.63-1000pg/mL
Sample type Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=50μL
Reaction time 45min Research Area CD & Adhesion molecule;Tumor immunity;Infection immunity;
Test principle This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Rat ACTH. Standards or samples are added to the appropriate micro ELISA plate wells then with a biotin-conjugated antibody specific to Rat ACTH. Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat ACTH in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(pg/mL) OD
1000.00 0.256
500.00 0.356
250.00 0.550
125.00 0.811
62.50 1.106
31.25 1.501
15.63 1.815
0.00 2.479
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(pg/mL) 5.23 204.78 456.83 28.07 185.48 484.29
Standard deviation 2.97 7.00 23.45 2.81 9.83 17.10
C V (%) 7.44 4.48 4.34 3.03 3.14 4.02
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 80-95 87
EDTA plasma (n=8) 87-99 93
Cell culture media (n=8) 87-99 93
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 86-101 89-102 87-102
Average (%) 99 90 87
1:4 Range (%) 86-101 89-102 85-96
Average (%) 95 99 90
1:8 Range (%) 87-96 92-101 87-101
Average (%) 93 100 96
1:16 Range (%) 92-105 88-102 89-102
Average (%) 100 89 92