PRODUCTS

Catalog Number:RE5470H
Human MCCC1(Methylcrotonoyl-CoA carboxylase subunit alpha, mitochondrial) ELISA Kit
Copy Product Information

Size:

96 T

48 T

Price:

Inquiry

Inquiry

Delivery: Order now, ship in 3 days

Product Details
Product Name Human MCCC1(Methylcrotonoyl-CoA carboxylase subunit alpha, mitochondrial) ELISA Kit Species Human
Uniprot ID Q96RQ3 Alternative Names 3-methylcrotonyl-CoA carboxylase 1,3-methylcrotonyl-CoA carboxylase biotin-containing subunit,3-methylcrotonyl-CoA:carbon dioxide ligase subunit alpha,MCCase subunit alpha,MCCA,MCCC1
Detection method Sandwich Sensitivity 0.14 ng/mL
Standard 20ng/mL Detection Range 0.31-20ng/mL
Sample type Serum, Plasma and Other biological fluids;Sample Volume=100μL
Reaction time 3.5H Research Area CD & Adhesion molecule;
Test principle N/A
Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(ng/mL) OD Corrected
20.00 2.356 2.282
10.00 1.683 1.609
5.00 1.287 1.213
2.50 0.585 0.511
1.25 0.352 0.278
0.63 0.234 0.160
0.31 0.136 0.062
0.00 0.074
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(ng/mL) 0.828 2.249 12.100 0.717 2.349 12.10
Standard deviation 0.036 0.113 0.522 0.055 0.092 0.726
C V (%) 4.33 5.01 4.31 7.66 3.9 6.00
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 94-103 99
EDTA plasma (n=8) 95 96
Cell culture media (n=8) 97 97
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 96-104 98-107 89-97
Average (%) 99 102 93
1:4 Range (%) 90-98 94-102 89-98
Average (%) 95 98 94
1:8 Range (%) 95-105 94-101 94-102
Average (%) 100 97 97
1:16 Range (%) 94-100 90-96 96-104
Average (%) 97 93 100