Catalog Number:RE5420H
Human PCCA(Propionyl-CoA carboxylase alpha chain, mitochondrial) ELISA Kit
Copy Product Information

Size:

96 T

48 T

Price:

Inquiry

Inquiry

Delivery: Order now, ship in 3 days

Product Details
Product Name Human PCCA(Propionyl-CoA carboxylase alpha chain, mitochondrial) ELISA Kit Species Human
Uniprot ID P05165 Alternative Names PCCase subunit alpha,Propanoyl-CoA:carbon dioxide ligase subunit alpha,Propionyl-CoA carboxylase alpha chain, mitochondrial
Detection method Sandwich Sensitivity 0.05 ng/mL
Standard 10ng/mL Detection Range 0.16-10ng/mL
Sample type Serum, Plasma and Other biological fluids;Sample Volume=100μL
Reaction time 3.5H Research Area Cardiovascular,Signaling transduction,Neuroscience,Cancer,Metabolism
Test principle N/A
Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(ng/mL) OD Corrected
10.00 2.313 2.253
5.00 1.786 1.726
2.50 1.263 1.203
1.25 0.593 0.533
0.63 0.367 0.307
0.31 0.241 0.181
0.16 0.116 0.056
0.00 0.060
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(ng/mL) 0.308 1.497 6.445 0.387 1.816 6.04
Standard deviation 0.019 0.101 0.374 0.026 0.142 0.472
C V (%) 6.05 6.72 5.80 6.84 7.8 7.82
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 89-96 92
EDTA plasma (n=8) 93 97
Cell culture media (n=8) 100 97
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 97-104 91-99 97-103
Average (%) 101 94 100
1:4 Range (%) 97-106 90-99 93-102
Average (%) 101 94 98
1:8 Range (%) 92-100 96-105 94-101
Average (%) 95 100 98
1:16 Range (%) 89-97 93-102 90-96
Average (%) 92 97 93