PRODUCTS

Catalog Number:FS1094M
FS-Mouse TIMP-1(Tissue Inhibitors of Metalloproteinase 1) ELISA Kit
Copy Product Information

Size:

96 T

48 T

Price:

$459.00

$329.00

Delivery: Order now, ship in 3 days

Product Details
Product Name FS-Mouse TIMP-1(Tissue Inhibitors of Metalloproteinase 1) ELISA Kit Species Mouse
Uniprot ID P12032 Alternative Names CLGI, Collagenase inhibitor, collagenase inhibitor), EPATIMP-1, EPO, erythroid potentiating activity, Erythroid-potentiating activity, Fibroblast collagenase inhibitor, FLJ90373, HCI, metalloproteinase inhibitor 1, TIMP metallopeptidase inhibitor 1, TIMP1, TIMP-1, TIMPtissue inhibitor of metalloproteinase 1 (erythroid potentiating activity, Tissue inhibitor of metalloproteinases 1
Detection method Sandwich Sensitivity 25.41 pg/mL
Standard 5000pg/mL Detection Range 78.13-5000pg/mL
Sample type Serum, Plasma;Sample Volume=50μL
Reaction time 1.5H Research Area Infection immunity;Hematology;
Test principle This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse TIMP-1. Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for Mouse TIMP-1 are added to the micro ELISA plate wells. Mouse TIMP-1 in samples (or standards) combines with the coated antibody and HRP linked detection antibody special to Mouse TIMP-1. Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450±2 nm. The OD value is proportional to the concentration of Mouse TIMP-1. The concentration of Mouse TIMP-1 in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(pg/mL) OD Corrected
5000.00 2.975 2.958
2500.00 2.028 2.011
1250.00 1.167 1.150
625.00 0.678 0.661
312.50 0.371 0.354
156.25 0.194 0.177
78.13 0.109 0.092
0.00 0.017 0.000
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(pg/mL) 3178.784 1789.090 2109.269 2735.440 4037.058 214.725
Standard deviation 8.828 0.431 8.324 7.047 4.785 14.400
C V (%) 3.591 7.885 7.812 7.718 9.133 7.371
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 93-113 101
EDTA plasma (n=8) 94-101 97
Cell culture media (n=8) 83-111 92
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 88-110 91-112 84-110
Average (%) 104 100 99
1:4 Range (%) 89-111 102-107 96-107
Average (%) 98 107 106
1:8 Range (%) 98-108 95-113 83-117
Average (%) 104 110 114
1:16 Range (%) 83-115 102-110 90-112
Average (%) 104 106 102
Assay Procedures