PRODUCTS

Catalog Number:RE1048R
Rat IL-1ra/IL-1F3(Interleukin 1 Receptor Antagonist) ELISA Kit
Copy Product Information

Size:

96 T

48 T

Price:

$399.00

$279.00

Delivery: Order now, ship in 3 days

Product Details
Product Name Rat IL-1ra/IL-1F3(Interleukin 1 Receptor Antagonist) ELISA Kit Species Rat
Uniprot ID P25086 Alternative Names IL1RN, DIRA, ICIL-1RA, IL-1RN, IL-1RA, IL-1ra3, IL1F3, IL1RA, IRAP, MVCD4
Detection method Sandwich Sensitivity 46.88 pg/mL
Standard 5000pg/mL Detection Range 78.13-5000pg/mL
Sample type Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL
Reaction time 3.5H Research Area Signal transduction;Tumor immunity;
Test principle This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Rat IL-1ra/IL-1F3. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat IL-1ra/IL-1F3 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat IL-1ra/IL-1F3, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Rat IL-1ra/IL-1F3. You can calculate the concentration of Rat IL-1ra/IL-1F3 in the samples by comparing the OD of the samples to the standard curve.
Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(pg/mL) OD Corrected
5000.00 2.465 2.435
2500.00 1.609 1.579
1250.00 0.943 0.913
625.00 0.424 0.394
312.50 0.215 0.185
156.25 0.117 0.087
78.13 0.065 0.035
0.00 0.030 0.000
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(pg/mL) 139.13 718.75 1962.35 112.80 1052.84 1327.16
Standard deviation 4.16 33.77 112.72 6.91 59.52 98.46
C V (%) 3.70 3.47 3.68 6.10 3.14 2.80
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 82-96 87
EDTA plasma (n=8) 86-97 92
Cell culture media (n=8) 84-103 96
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 89-97 96-101 87-98
Average (%) 90 98 93
1:4 Range (%) 86-102 85-92 92-104
Average (%) 87 87 98
1:8 Range (%) 94-106 80-96 82-96
Average (%) 105 93 94
1:16 Range (%) 85-97 89-101 95-102
Average (%) 88 98 102
Assay Procedures