PRODUCTS

Catalog Number:RE3075R
Rat CX37(Connexin 37) ELISA Kit
Copy Product Information

Size:

96 T

48 T

Price:

$399.00

$279.00

Delivery: Order now, ship in 3 days

Product Details
Product Name Rat CX37(Connexin 37) ELISA Kit Species Rat
Uniprot ID N/A Alternative Names GJA4, gap junction protein alpha 4,Gap junction alpha-4 protein,Connexin-37,Cx37
Detection method Sandwich Sensitivity 0.1 ng/mL
Standard 10ng/mL Detection Range 0.16-10ng/mL
Sample type Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL
Reaction time 3.5H Research Area Immune molecule;
Test principle This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Rat CX37. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat CX37 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat CX37, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Rat CX37. You can calculate the concentration of Rat CX37 in the samples by comparing the OD of the samples to the standard curve.
Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(ng/mL) OD Corrected
10.00 2.383 2.358
5.00 1.698 1.673
2.50 0.982 0.957
1.25 0.475 0.450
0.63 0.236 0.211
0.32 0.113 0.088
0.16 0.066 0.041
0.00 0.025 0.000
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(ng/mL) 0.23 1.58 4.34 0.29 2.23 2.86
Standard deviation 0.01 0.13 0.20 0.01 0.09 0.20
C V (%) 6.93 4.71 6.13 6.78 4.95 5.00
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 84-103 96
EDTA plasma (n=8) 82-96 87
Cell culture media (n=8) 86-97 92
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 95-102 89-99 95-105
Average (%) 97 95 99
1:4 Range (%) 98-106 89-99 86-97
Average (%) 100 90 96
1:8 Range (%) 87-98 88-104 83-96
Average (%) 92 90 91
1:16 Range (%) 91-102 84-98 91-103
Average (%) 101 87 94
Assay Procedures